GENASUN BOOST MPPT – GVB-8 LEAD-ACID 24V
Genasun BOOST solves the serial connection problem
You might already be aware that if you connect your solar panels in series you increase the probability of a reduced lifespan on the solar panels. Besides that for a serial connection a by-pass diode is required which will decrease the output. Furthermore during partial shadowing which is common among our customers a serial connection will underperform in comparison with the parallel setup. The MoonRay controller solves this and more for a 12V system but for 24V, 48V and 52V battery systems you should choose the Genasun Boost controller for the best performance and health of your solar panels.
Tested and approved for all environments
Genasun controllers are deployed to the most remote locations on earth. They endure years at sea, harsh Antarctic winters, freezing conditions in the upper atmosphere on solar-powered airplanes, and in a few off-the-map locations. Made in the USA, each controller is put through complete electrical testing to ensure reliability. If you need mission-critical power, this is your controller.
High-Speed MPPT: Always on Target
Not all Maximum Power Point Tracking controllers were created equally. Most use a sweep and sleep method that scans the entire voltage range every 30-60 seconds. That’s okay for a clear day, but traditional controllers are constantly off target during changing cloud conditions – exactly when power is scarce and is needed the most. Genasun controllers adapt to changing light conditions 20 times every second. They are always on target, capturing every bit of available sunshine. Simply put, other controllers can’t keep up.
Computer-controlled, temperature-compensated 3-stage battery charging
Precise computer controlled charging ensures the optimal charge cycle for your battery. This increases the battery life, and maximizes battery capacity.
FEATURES
LED Indicator
The built-in LED will quickly tell you that you’ve installed the controller correctly. Simple to read, it will also let you know when the battery is charging from solar power, and when the battery has reached full charge.
Marine Grade: Reliable Power After Years at Sea
Genasun Boost controllers provide reliable power in the harshest environments on earth. GVB’s have been powering boats on round-the-world sailing races for years..
No Fans. No Relays.
Fans get clogged with dust and dirt. Relays eventually stop switching. Genasun controllers use advanced electrical design that obsoletes these parts. With fewer moving parts to wear out, Genasun controllers outlast the competition.
TECHNICAL OVERVIEW
GVB-8-Pb-24V | |||
Rated Panel Input Current | 8A* | ||
---|---|---|---|
Minimum Panel Voltage for Charging | 5V | ||
Minimum Battery Voltage for Operation | 9.5V | ||
Maximum Input Panel | 60V | ||
Recom. Max Panel Voc at STC | 50V | ||
Input Voltage Range | 0-60V | ||
Maximum Charge Voltage | 28.8V | ||
Maximum Input Short Circuit Current** | 8A* | ||
Maximum Input Current*** | 15A | ||
Tracking Efficiency | 99+% typical | ||
MPPT Tracking Speed | 15Hz | ||
Charge Profile | Multi-Stage with Temperature Compensation | ||
Nominal Battery Voltage | 24V | ||
Maximum Recommended Panel Vmp | 26V | ||
Maximum Recommended Panel Power | 210W | ||
Bulk Voltage (Pb models) | 28.8V | ||
Absorption Voltage | 28.4V | ||
Absorption Time | 2 Hours | ||
Float Voltage (Pb models) | 27.6V | ||
Electrical Efficiency | 96%-98% typical | ||
Night Consumption | 6mA | ||
Battery Temperature Compensation | -56mV/°C | ||
Maximum Full Power Ambient | 70°C | ||
Environmental Protection | IP40 (Terminals Nickel Plated) | ||
Connection | 4-position terminal block for 10-30AWG wire | ||
Certifications | cETLus Safety, Recognized Component cETLus HazLoc (C1D2), CE, FCC, RoHS | ||
Weight (DiL) | 6.5 oz., 185g | ||
Dimensions | 5.5 x 2.5 x 1.2″, 14 x 6.5 x 3.1 cm | ||
Warranty | 5 years |
*Panel ratings have increased since we designed the GVB. Although we don’t believe in changing specifications without a corresponding engineering change, based on both our customers’ experiences over the years as well as the headroom we designed into the GVB, we feel comfortable recommending the GVB for panels with Imp up to 9A.
**Panel Isc. Maximum input power and maximum input voltage requirements must also be respected.
***Maximum current that the controller could draw from an unlimited source. This specification is not intended for determining PV input.
GVB-8-Pb-12V | GVB-8-Pb-24V | GVB-8-Pb-48V | |
Rated Panel Input Current | 8A* | ||
---|---|---|---|
Minimum Panel Voltage for Charging | 5V | ||
Minimum Battery Voltage for Operation | 9.5V | ||
Maximum Input Panel | 60V | ||
Recom. Max Panel Voc at STC | 50V | ||
Input Voltage Range | 0-60V | ||
Maximum Input Short Circuit Current** | 8A* | ||
Maximum Input Current*** | 15A | ||
Tracking Efficiency | 99+% typical | ||
MPPT Tracking Speed | 15Hz | ||
Charge Profile | Multi-Stage with Temperature Compensation | ||
Nominal Battery Voltage | 12V | 24V | 48V |
Maximum Recommended Panel Vmp | 13V | 26V | 43V |
Maximum Recommended Panel Power | 105W | 210W | 350W |
Bulk Voltage (Pb models) | 14.4V | 28.8V | 57.6V |
Absorption Voltage | 14.2V | 28.4V | 56.8V |
Absorption Time | 2 Hours | ||
Float Voltage (Pb models) | 13.8V | 27.6V | 55.2V |
Electrical Efficiency | 95%-97% typical | 96%-98% typical | 96%-99% typical |
Night Consumption | 7mA | 6mA | 5mA |
Battery Temperature Compensation | -28mV/°C | -56mV/°C | -112mV/°C |
Maximum Full Power Ambient | 70°C | ||
Environmental Protection | IP40 (Terminals Nickel Plated) | ||
Connection | 4-position terminal block for 10-30AWG wire | ||
Certifications | cETLus Safety, Recognized Component cETLus HazLoc (C1D2), CE, FCC, RoHS | ||
Weight (DiL) | 6.5 oz., 185g | ||
Dimensions | 5.5 x 2.5 x 1.2″, 14 x 6.5 x 3.1 cm | ||
Warranty | 5 years |